You need an air purifier whose smoke CADR is at least two-thirds of your room’s square footage, which is AHAM’s 2/3 rule. AHAM’s own example: a 10-by-12-foot room of 120 square feet needs a smoke CADR of at least 80. EPA’s sizing chart lands close by, with a minimum CADR of 130 for 200 square feet.
That sizing assumes an 8-foot ceiling and top fan speed. EPA says to size up for taller ceilings and to count the whole space in an open floor plan, and warns that CADR at lower speeds may be considerably lower. For wildfire smoke, AHAM asks for more: a smoke CADR equal to the room’s square feet. Be careful with big coverage numbers on a box.
How to size a purifier in three steps
- Measure the floor. Multiply length by width to get square feet.
- Apply AHAM’s 2/3 rule. Multiply the square feet by 2/3. The answer is the smoke CADR you should look for.
- Compare smoke CADR, not the headline. EPA says to choose a high tobacco smoke CADR to remove small particles.
AHAM’s rule and EPA’s chart are close. Here they are side by side. The right-hand column is our arithmetic.
| Room size | EPA’s minimum CADR | AHAM’s 2/3 rule (our arithmetic) |
|---|---|---|
| 100 sq ft | 65 | 67 |
| 200 sq ft | 130 | 133 |
| 300 sq ft | 195 | 200 |
| 400 sq ft | 260 | 267 |
| 500 sq ft | 325 | 333 |
| 600 sq ft | 390 | 400 |
EPA says its chart is calculated for an 8-foot ceiling and meant for estimation. A rule of thumb is all it claims to be.
A worked example (our arithmetic)
- A 14-by-16-foot bedroom is 224 square feet. Two-thirds of that is about 150.
- The ENERGY STAR dataset lists a smoke CADR of 161 for the Levoit Eleva 300X, and Levoit rates it for 250 sq ft at 4.8 air changes. That clears the target.
- The Levoit Core 300-P, at a smoke CADR of 143 by Levoit’s figure, falls just short for this room.
What CADR measures and what it leaves out
CADR is AHAM’s measure of how much filtered air a unit delivers, with separate scores for tobacco smoke, pollen and dust. EPA says those stand for small, medium and large particles.
EPA also says the rating is typically measured at the highest speed. At lower airflow settings, EPA says the CADR may not be known and could be considerably lower. EPA also says noise often leads people to switch units off, so a little headroom may let you use a lower speed.
Two things CADR will not tell you. EPA says it covers particles only, and that there are no widely used performance rating systems for filters designed to remove gases. For gases, look at carbon instead.
AHAM’s directory lists models independently verified at a third-party lab, searchable by CADR and room size. Consumer Reports describes the program as voluntary, and says that with the AHAM seal you can trust the unit can handle the suggested room size.
Why coverage claims vary so much
Coverage depends on how many times an hour the air is meant to be cleaned. A unit that “covers” 1,800 sq ft at one air change an hour covers far less at nearly five. Here is what each brand or seller states:
| Model | Big number on the page | At 4.8 air changes |
|---|---|---|
| Medify MA-25 | 413 sq ft (2 air changes) | 172 sq ft, Medify |
| Medify MA-40 | 896 sq ft (2 air changes) | 373 sq ft, Medify |
| Levoit Core 300-P | 1,066 sq ft (1 air change) | 222 sq ft, Levoit |
| Levoit Core 600S-P | 2,909 sq ft (1 air change) | 606 sq ft, Levoit |
| Coway Mighty2 | 1,800 sq ft (1 air change) | Not stated; 372 sq ft by AHAM’s formula (our arithmetic) |
| Shark HP302 | 1,400 sq ft in one hour | Not stated |
| Alen 45i | 1,900 sq ft an hour; 950 sq ft in 30 minutes | Not stated; HouseFresh gives 297 sq ft at 5 air changes |
| Honeywell HPA5100B | A retail title at Walmart says 900 sq ft | 190 sq ft, Honeywell; Sylvane lists up to 155 sq ft |
AHAM’s formula explains the 4.8 figure. Suggested room size equals smoke CADR times 1.55, based on reducing smoke particle concentration by 80% at steady state. With an 8-foot ceiling, AHAM calculates 4.84 air changes and rounds down to 4.8.
HouseFresh, which runs its own tests, says “many brands overstate the cleaning performance of their units.” It is one more reason to size from a CADR, not a slogan. Our guide to True HEPA wording covers the same problem on the filter label.

For the most floor area · Mid-range price range
Levoit Core 600S-P
Levoit rates it for 606 sq ft at 4.8 air changes, and the ENERGY STAR dataset lists a smoke CADR of 391. RTINGS finds it noticeably louder than a rival it compares, and HouseFresh says the filter is not rated HEPA.
View product details ›How many air changes do you actually need?
The sources do not agree on one number, and each is answering a slightly different question.
- AHAM: says the minimum ventilation recommendation found by researchers is 3 air changes per hour, and calls 4.8 well above it.
- CDC/NIOSH: says to aim for 5 or more air changes of clean air, calls this a rough guide, and says 5 will not guarantee totally safe air in any space.
- Harvard Healthy Buildings Program: also sets its clean-air target at 5 or more.
- HouseFresh: a tester’s choice, it states recommended room sizes at 5 air changes in its allergy guide.
- AHAM for wildfire smoke: a smoke CADR equal to the room’s square feet moves a unit from 4.8 to 7.5 equivalent air changes.
Run AHAM’s formula yourself to compare: air changes equal smoke CADR times 60, divided by room volume in cubic feet. A smoke CADR of 240 in a 300 sq ft room with an 8-foot ceiling gives 6 air changes (our arithmetic). The 2/3 rule works out to 5 at that ceiling height (also our arithmetic).
Our earlier guide on whether HEPA air purifiers work explains why a lower particle count should not be read as a health promise.
Tall ceilings, open plans and two units
EPA says that with ceilings above 8 feet you should consider a cleaner sized for a larger area. Take the 224 sq ft bedroom above with a 10-foot ceiling: holding 4.8 air changes takes a smoke CADR of about 179 rather than about 143 (our arithmetic from AHAM’s formula).
For an open floor plan, EPA says to consider the entire space the unit would serve. Our guide to HEPA air purifiers for large rooms is sized on that basis, and HEPA air purifiers for bedrooms covers low-speed noise in smaller rooms.
Two units can beat one. Harvard says the cleaning benefit of multiple units is additive, and that several smaller units around a room may be more effective than one large unit of the same total CADR, because air is not uniformly mixed. EPA says a portable cleaner cleans a single room, so separate rooms need separate units.

For a medium room · Mid-range price range
Medify MA-40
Medify describes it as AHAM Verifide at 373 sq ft for 4.8 air changes, with a smoke CADR of 239. Medify lists 40.5 to 53.3 dBA; HouseFresh measured 46 to 66 dB.
See today’s price ›Honest note
Every number here is a lab rating or a calculation, and none of them describes your room. EPA says open doors and windows make a unit much less effective for a room, and it calls its chart an estimate. Some brands also leave gaps: Shark’s page lists no CADR, and IQAir publishes airflow instead. We have not tested or used these air purifiers ourselves; room sizes and CADR figures are the brand’s, or the source named.
Questions people ask
What CADR do I need for a 300 sq ft room?
About 195 to 200. EPA’s chart gives a minimum CADR of 195 for 300 square feet with an 8-foot ceiling, and AHAM’s 2/3 rule gives 200 by our arithmetic. For wildfire smoke, AHAM recommends a smoke CADR equal to the square footage, so 300.
Why does a listing say 1,800 sq ft when the rule says far less?
It uses fewer air changes. Coway states 1,800 sq ft for the Mighty2 at one air change per hour, and 450 sq ft in 15 minutes in its manual. AHAM’s formula on its smoke CADR of 240 gives 372 sq ft by our arithmetic.
Which CADR should I look at: smoke, dust or pollen?
Smoke, for sizing. AHAM’s 2/3 rule and its room-size formula both use the smoke score. EPA says tobacco smoke, dust and pollen CADRs stand for small, medium and large particles, and advises a high tobacco smoke CADR to remove small particles.
Does ceiling height matter?
Yes. EPA’s chart assumes an 8-foot ceiling and says to consider a unit sized for a larger area when ceilings are taller. AHAM’s formula for any room is smoke CADR times 60, divided by the room’s volume in cubic feet.
Is one large purifier or two small ones better?
Two can do better in one big room. Harvard says the benefit of multiple units is additive and that several smaller units may be more effective than one large unit of the same total CADR, because air in a room is not uniformly mixed.
Read first: best HEPA air purifier · hepa air purifiers for large rooms
Sources: AHAM: Air filtration standards · AHAM: White paper on portable air cleaners and air changes per hour · EPA: Guide to air cleaners in the home · CDC/NIOSH: Aim for 5 air changes · Harvard Healthy Buildings Program: Portable air cleaners · Consumer Reports: Air purifier buying guide
This article is general information, not medical advice. An air purifier does not treat allergies, asthma or any other condition; talk to your doctor about symptoms, and follow the maker’s instructions for use and filter changes. Specifications are each brand’s own.